Off-center load cell TA9I


Download PDF

Off-center load cell for weighing systems, automatic dosage machines, medical, food, textile, and automation in general

OFF-CENTER LOAD CELL


Zoom Click to enlarge image

Off-center load cell TA9I Off-center load cell TA9I Schema
ATEX OIML

Technical Specifications

MaterialStainless steel
Nominal load8, 10, 15, 20, 30, 50 ,75, 100, 150, 200 kg
Limit load150 % F.S.
Breaking load300 % F.S.
Supply voltageMaximum 18 V dc
Output2 mV/V
Output tollerance0,1 % F.S.
Zero tollerance1,5 % F.S.
Linearity0,03 % F.S.
Hysteresis0,03 % F.S.
Input resistance400 - 460 ohm
Output resistance350-353 ohm
Insulation resistance>= 5000 mW
Thermal compensation-10 / +40°C (14 / +104°F)
Operating temperature-35 / +65°C (-31 / +149°F)
Temperature deviation zero0,003 % F.S. / °C
Temperature deviation full scale0,002 % F.S. / °C
Protection classIP 67
Standard cable length1 m – 6 x 0,35 (shield not connected to the load cell body)
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means